Standard
-
Rotating electrical machines - Rating and performance.(GB755-2008)
-
Test procedures for three-phase induction motors.(GB1032-2012)
-
Test procedure for direct current machines.(GB1311-2008 )
-
General requirements for safety of small and medium size rotating electrical machines.(GB14711-2006)
-
Standard for hand-over test of electric equipment electric equipment installation engineering.(GB 50150)
-
Code for design of electric distribution of general-purpose utilization equipment.(GB 50055-93)
-
General technical specifications for high voltage test equipments.(DL/T846-2004)
-
Safety requirements for electronic measuring apparatus.(GB4793-1984)
Main technical parameters
-
Supply voltage: 220V±5﹪; 50Hz/60 Hz±2﹪.
-
Output voltage: 0~5kV
-
Rated capacity: 5Kva
-
Breakdown current: 5mA-500mA, Optional setting, continuous adjustable,Precision2﹪
-
The time range can be set of test: 1s~99s
-
Figures show , automatic control functions and Configuring industrial printer
-
The earthing protection device, ensure the safety of test personnel
-
Applicable to 1140V∕500W below the machine power frequency voltage withstand test or single line (Forming coil) voltage withstand test
|